Honeywell AirScan™ IR-F9 R407a

Honeywell AirScan™ IR-F9 R407a

Honeywell AirScan™ IR-F9 R507a

Honeywell AirScan™ IR-F9 R507a

Honeywell AirScan™ IR-F9 R410a

* Price includes current tariff charges by Honeywell. *

$0.00
SKU
R410a HON00M

Honeywell AirScan™ IR-F9 -

The AirScan™ IR-F9  is an infared diffusion design sensor that allows all points of detection to be monitored simultaneously. With the SensorCheck™ technology you can continuously monitor your sensors perfromance by testing the sensor every 24 hours for electrical viability. This device is versatile allowing it ot be used with any Honeywll Analytics readout and can respond to refrigerants in the rang eof 0-3,000ppm. The device is available in either aluminum and stainless steel enclosures and can come with or with out the ATMOS™ technology. ATMOS allows for your device to operate in environments with tempearatures as low as -60°F. 

AirScan™ IR-F9 Datasheet 
AirScan™ IR-F9 Specification Sheet

Specifications
Part Number AirScan Description
M-700075 R410a 0-1,000 ppm, NEMA1 enclosure
M-700076 R410a 0-1,000 ppm, stainless steel enclosure
M-700077 R410a 0-1,000 ppm, ATMOS, NEMA1 enclosure
M-700078 R410a 0-1,000 ppm, ATMOS, stainless steel enclosure
M-700079 R410a 0-1,000 ppm, ATMOS, super heat, NEMA1 enclosure
M-700080 R410a 0-1,000 ppm, ATMOS, super heat, stainless steel enclosure
M-700085 R410a 0-3,000 ppm, NEMA1 enclosure
M-700086 R410a 0-3,000 ppm, stainless steel enclosure
M-700087 R410a 0-3,000 ppm, ATMOS, NEMA1 enclosure
M-700088 R410a 0-3,000 ppm, ATMOS, stainless steel enclosure
M-700089 R410a 0-3,000 ppm, ATMOS, super heat, NEMA1 enclosure
M-700090 R410a 0-3,000 ppm, ATMOS, super heat, stainless steel enclosure
M-700081 R410a 0-1,000 ppm
M-700091 R410a 0-3,000 ppm

Features: 

- Refrigerant Specific: Rapid reponse to refrigerants including R-404a, R-22, R-507a, R-134a, R-407a, R-410a, R-422d, HFO-1234yf, NH3 and CO2
- Internal monitoring of 4/20 mA loop circuitry continuously
- Compliant with new monitoring standards set by CARB
- Has no moving pumps and doesnt require pumps or filters
- All points of detection can be monitored continuously at an affordable cost
- Can be used with any Honeywell Analytics readout
- Standard range of 0-3,000 ppm can be rescaled for lower trip points
- Simple, real-time calibration eliminates maintenance downtime
- Automatically adapts to fluctuating temperatures

Applications:

Banana and Produce Rooms
- Beverage Plants
- Wineries and Breweries
- Confined Space Entry
- Food Processing
- Gas Bottling Plants
- Ice Rinks
- Product Coolers
- Rack Houses
- Refrigeration Systems
- Supermarkets