The AirScan™ IR-F9  is an infared diffusion design sensor that allows all points of detection to be monitored simultaneously. With the SensorCheck™ technology you can continuously monitor your sensors perfromance by testing the sensor every 24 hours for electrical viability. This device is versatile allowing it ot be used with any Honeywll Analytics readout and can respond to refrigerants in the rang eof 0-3,000ppm. The device is available in either aluminum and stainless steel enclosures and can come with or with out the ATMOS™ technology. ATMOS allows for your device to operate in environments with tempearatures as low as -60°F.

AirScan™ IR-F9 Datasheet
AirScan™ IR-F9 Specification Sheet

Specifications
Part Number AirScan Description
M-700261 HFO1234yf 0/500, NEMA 1 enclosure, CARBcompliant
M-700262 HFO1234yf 0/500, ATMOS, NEMA 1 enclosure, CARBcompliant
M-700263 HFO1234yf 0/500, stainless steel enclosure, CARBcompliant
M-700264 HFO1234yf 0/500, ATMOS, Stainless Steel Enclosure, CARBcompliant
M-700266 HFO1234yf 0/1000, NEMA 1 enclosure
M-700267 HFO1234yf 0/1000, ATMOS, NEMA 1 enclosure
M-700268 HFO1234yf 0/1000, ATMOS, NEMA 1 enclosure
M-700269 HFO1234yf 0/1000, ATMOS, stainless steel enclosure
M-700271 HFO1234yf 0/3000, NEMA 1 enclosure
M-700272 HFO1234yf 0/3000, ATMOS, NEMA 1 enclosure
M-700273 HFO1234yf 0/3000, ATMOS, NEMA 1 enclosure
M-700274 HFO1234yf 0/3000, ATMOS, stainless steel enclosure
M-700265 HFO1234yf 0-500 ppm, CARB compliant
M-700270 HFO1234YF 0-1000 ppm
M-700275 HFO1234YF 0-3000 ppm

Features:

- Refrigerant Specific: Rapid reponse to refrigerants including R-404a, R-22, R-507a, R-134a, R-407a, R-410a, R-422d, HFO-1234yf, NH3 and CO2
- Internal monitoring of 4/20 mA loop circuitry continuously
- Compliant with new monitoring standards set by CARB
- Has no moving pumps and doesnt require pumps or filters
- All points of detection can be monitored continuously at an affordable cost
- Can be used with any Honeywell Analytics readout
- Standard range of 0-3,000 ppm can be rescaled for lower trip points
- Simple, real-time calibration eliminates maintenance downtime
- Automatically adapts to fluctuating temperatures

Applications:

Banana and Produce Rooms
- Beverage Plants
- Wineries and Breweries
- Confined Space Entry
- Food Processing
- Gas Bottling Plants
- Ice Rinks
- Product Coolers
- Rack Houses
- Refrigeration Systems
- Supermarkets