RKI Replacement CO Sensor ESR-A13P-CO for GX-3R

RKI Replacement CO Sensor ESR-A13P-CO for GX-3R

RKI Replacement CO with H2 Compensation Sensor ESR-A1CP-CO-H for GX-3R

$255.00
SKU
ESR-A1CP-CO-H

RKI Replacement CO with H2 compensation Sensor ESR-A1CP-CO-H for GX-3R -

Part Number Description
ESR-A1CP-CO-H CO with H2 Compensation Sensor

CO with H2 Compensation Safety Data Sheet

Specifications
Gas Detected (CO)
H2 Compensated
Carbon Monoxide(CO) Hydrogen Sulfide(H2S) H2S
Only
Combustible Gases
(Methane as standard)
Oxygen
Dual Sensor
Sensor Slot 1 2
3
Detection
Principle
EC Dual EC EC Catalytic combustion
EC
Detection Range
(Increments)
0 ~ 2,000 ppm
(1 ppm)
0 ~ 200.0 ppm
(0.1 ppm)
0 ~ 100% LEL
(1% LEL)
0 ~ 40% Vol. (0.1%)
Accuracy
Statement
± 5% of reading
or ± 2 ppm CO
± 5% of reading
or ± 5 ppm CO
(whichever is greater)
± 5% of reading
or ± 2 ppm H2S
(whichever is greater)
± 5% of reading
or ± 2% LEL
(whichever is greater)
± 0.5% of reading O2
Sampling Method Diffusion sampling standard (hand aspirator or clip-on motorized pump optional)
Display Digital LCD displays with 7 segment plus 14 segment plus icon
Preset Alarms
(User Adjustable)
Overscale alarm
(Non-adjustable)
1st alarm: 25.0 ppm
2nd alarm: 50.0 ppm
3rd alarm: 1200.0 ppm
TWA alarm: 25.0 ppm
STEL alarm: 200.0 ppm
Over alarm: 2000.0 ppm
1st alarm: 5.0 ppm
2nd alarm: 30.0 ppm
3rd alarm: 100.0 ppm
TWA alarm: 1.0 ppm
STEL alarm: 5.0 ppm
Over alarm: 200.0 ppm
1st alarm: 10% LEL
2nd alarm: 25% LEL
3rd alarm: 50% LEL
Over alarm: 100% LEL
 
Types of Alarms Gas Alarm: 3 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing.
Trouble alarm: Sensor disconnection, low battery, circuit error, calibration range error
Display of Alarm Gas Alarm: Flashing LEDs, continuous buzzer (100 db @ 30 cm), flashing gas value, vibration
Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message
Operating Temp.
& Humidity
-20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment)
-40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes)
Response Time Within 30 seconds (T90)
Power Source Lithium-ion battery, Approx. 25 hours after a 3 hour full charge
Approvals ATEX,  CSA, IECEx, MED
Dimension
& Weight
2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm), 3.52 ounces (approx. 100 g) without rubber booth
2.4” W x 2.63” H x 1.06” D (Approx. 61 W x 67 H x 27 D mm), 3.70 ounces (approx. 105 g) with rubber booth
Case Material Dust and water resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft
Controls Two buttons: POWER / MODE, AIR
Datalogging Logs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Interval Trends
Standard
Accessories
Alligator clip, protective rubber boot, charger, and calibration adapter
Optional
Accessories
SDM-3R calibration station
RP-3R Clip-on sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available)
Padded carrying case for GX-3R and accessories
USB to IrDA downloading cable for datalogger
Warranty Three years material and workmanship